Flo switch for sundance optima spa 1997

WebJan 22, 2024 · This item: Sundance Spas Heater Flow Switch W/Tee, 6560-857. $44.99. In Stock. Ships from and sold by Clearview Fireplace & Patio. Sundance Spa Temp Sensor #6600-167. $29.49. Only 7 left in stock - order soon. Sold by Warehouse 28 and ships from Amazon Fulfillment. Get it as soon as Friday, Mar 31. WebFits Sundance spas 1995 & newer; Includes High-Limit Sensor & Switch; Indicator lights for easy diagnostics; Product notes: Includes 1/4" sensor 6600-168, wire harness, extra 3/4” hose. Fits 1995+ 650 - 850 & 880 series with low flow heaters. Used on 2015+ Jacuzzi J-400 & J-500 spas. Use silicone sealant to secure sensor in sensor well.

Flow Switch Or Relay, That Is The Question. - Pool …

WebNov 26, 2024 · EXCELFU Flow Switch Assembly 6560-860 for Sundance Spas and Jacuzzi Hot Tub Used for Following Spa/Hot Tub Models: • All 1999+ 2 pump or 3 pump systems and 2001+ 1 Pump Capri Systems. • Sundance 800/850/880 Series: Maxxus, Optima, Cameo, Majesta, Altamar, Marin. • 1999+ Sweetwater and Portifino series with … WebSundance® Spas Air Blower Motor Assembly BLOWER: 1.0HP 220-240V THERM-PROTECTED 2005+ Sundance® Spas Capri®Blower motor assembly, 240 VAC.New high performance motor runs cooler and quieter.Compact size 9" x 6.5" x 6.75" equipped... float hosting domain https://chansonlaurentides.com

Manuals & User Guides SundanceSpas.com Sundance® Spas

WebOct 27, 2024 · Spoke too soon, IT started working heated up the hot tub, then went back to FLO2, I unhook the wiring harness from the control board and re-hooked it back up after checking connection now I’m getting a FLO ERROR, I’m pretty sure it must be the switch. WebReplacement Parts for Sundance Spa. Spa Hot tub parts listed are NON- Proprietary ( Generally Used ) equivalent spa parts. ( Generic replacement spa parts ) from the same spa part manufacture. Others are replacement spa parts that will work as well or better. The listing is meant as an aid in helping you find your replacement parts faster. WebSale Price: $796.00. Sundance® Spas. Click on MORE INFO. 6600-730 Circuit Board. Takes the place of 6600-028,6600-056 and 6600-092.Also replaces 6600-180 if used for previous boards with 1 Two Speed and 1 Single Speed Pump. New Version Replaced 6600-092 Sundance® Jacuzzi® Spas Circuit Board With Pump 1=2Spd, Pump 2 =1Spd, … float horse teeth

Solid FLO error 99 Sundance Optima - Portable Hot Tubs & Spas

Category:Troubleshooting An FL2 Error Code - Sundance® Spa Parts

Tags:Flo switch for sundance optima spa 1997

Flo switch for sundance optima spa 1997

6560-860, Sundance Spas - Hot Tub Flow Switch - amazon.com

WebFeb 17, 2012 · 2. We removed the filter, reset the power. Spa operates for over an hour without the FLO message but eventually reappears. 3. We place a water hose where the filter normally sits and FLO message disappears. Once the hose is removed, the FLO message reappears (approx. 20 minutes after the hose is removed). 4. WebProduct Description. Water Pro Series Smart Low-flow Hot Tub Heater Assembly is compatible for use in Sundance Spas. Features Titanium extended life element and meets or exceeds OEM spa heater specifications. You cannot buy a better replacement spa heater at any price. Includes 1/4" sensor 6600-168, high limit disk, wire harness, extra 3/4” hose.

Flo switch for sundance optima spa 1997

Did you know?

WebMar 29, 2024 · Almost always it’s an indication of a bad connection at the Flow switch and or a bad Flow switch. Do check the flow switch to make sure there is not debris wrapped around the paddle however before you install a new switch. Sometimes power cycling the spa for 15min will clear the FLO2 code but if it’s a bad Flow switch it will return again.

WebOct 30, 2016 · The first reason would be that the flow switch/pressure switch has failed and is delivering a closed circuit at all times. When functioning properly, this sensor should be delivering a closed circuit only when there is adequate water flow. If the sensor is functioning normally, it should measure OL or infinite when no water flow is detected. It ... WebRemove the equipment side cabinet panels and locate the drain plugs in the front of each pump. Remove these plugs to allow ater to drain out of the pumps and heater. 7. Loosen clamp at bottom of heater and pull hose off of heater fitting (twist the hose back and forth while pulling downward.

WebJan 22, 2024 · The FLO message returns when the pumps are stopped. The FLO message does not disappear when the single speed pump is running. At the moment the temperature indicates 102°F. It is set at 103°F. I have not been able to get the tub to its hottest temperature. In the past, the hottest temperature has been obviously too hot! WebThe smallest spa in the luxury 880 line is the Capri Spa, with room for up to 3 adults in a 5'9" x 6'10" x 30.5" spa shell. This spa has 31 jets total, 1 high flow spa pump and 1 circ pump. There are 3 mid size spas in this line. The first is the Marin spa, with room for up to 5 in a 6'4" x 7'7" x 33" shell.

WebSep 13, 2016 · FLOW SWITCH (heater is deactivated pump may also be deactivated) proper flow of water is inhibited or a flow switch has malfunctioned. Check for proper water level, and check for clogged stage 2 filter. FLO2-. CLOSED OR SHORTED FLOW SWITCH ON SYSTEM START-UP (system disabled) flow switch is non-functional.

WebSep 28, 2014 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features Press Copyright Contact us Creators ... great hearts san antonio 78251Oct 2, 2011 · float hosting nameserversWebDec 3, 2024 · I have a 2001 Sundance Cameo 850 series very similar to yours. I think you've nailed the possible causes on the head. 1. The circ pump is weak. 2. The flow switch is hard to close than it should be. 3. Something is restricting water flow whether it be the filter or something in the heater. As you mentioned, you could try to bend the prongs … float house abbotsfordWebNov 24, 2009 · Detailed video on how to replace Sundance Spas flow switch float homes torontoWebFits Sundance spas 1995 & newer; Includes High-Limit Sensor & Switch; Indicator lights for easy diagnostics; Product notes: Includes 1/4" sensor 6600-168, wire harness, extra 3/4” hose. Fits 1995+ 650 - 850 & 880 series with low flow heaters. Used on 2015+ Jacuzzi J-400 & J-500 spas. Use silicone sealant to secure sensor in sensor well. float hosting supportWebJan 7, 2024 · When jet pumps where off, flow switch was completely open at 45 degree, and the circulation pump was not not running. Knowing it was supposed to run 24/7, I opened the pump, cleaned it from hard water depot, reconnected the ground wire which was unseated probably because of vibration and putted it back in the tub. great hearts san antonio calendarWebJun 10, 2024 · Jun 6, 2024. #2. My Sundance manual says about a FLO2 error: "CLOSED OR SHORTED FLOW SWITCH ON. SYSTEM STARTUP (system disabled) Flow switch. is non-functional. This must be repaired only by a. dealer or qualified service organization. ". float house